Capsule Tech

 

ASDEX AS-9 Amalgam Separator

(ISO 11143 Certified ISO Rated 99.0%)
 


(2000D & MBK-1)

Single Chairside System Portable System/Mobile System

Item # Description Price
AS10S Complete System
Includes: 1 Manifold Head Assembly, 1-Mount Bracket, 1-Replacement Separator
(as-10) 14" long
$233.00
2000D Manifold Head Assembly $104.00
MBK-1 Mounting Bracket $30.00
AS-10 Replacement Separator 14" long $90.00
Mounting Space Required: 5"x14"
Average Life: 4-8 Months
Flow Rate: 1L/MN  ISO Rated: 99.0%
Replacement Schedule: When vacuum is depleted to mouthpiece or 1 year.
Dispose in accordance with any and all local, State & Government guidelines.


Central Vacuum System 2-4 Chairs

Item # Description Price
AS20S Complete System
Includes: 1-Manifold Head Assembly, 1-Mounting Bracket, 1-Replacement Separator (as-20) 24" long
$332.00
2000D Manifold Head Assembly $104.00
MBK-1 Mounting Bracket $30.00
AS-20 Replacement Separator 24" long $198.00
Mounting Space required 5"x 24"
Average Life: 4-8 Months
Flow Rate: 1L/MN  ISO Rated: 99.0%
Replacement Schedule: When vacuum is depleted to mouthpiece or 1 year.
Dispose in accordance with any and all local, State & Government guidelines.


For Portable & Mobile Systems

Item # Description Price
AS5S Complete System
Includes: 1 Manifold Assembly, 1-Mount Bracket, 1-Replacement Separator (AS-5) 7" Long
$204.00
200D Manifold Head Assembly $104.00
MBK-1 Mounting Bracket $130.00
AS-5 Replacement Separator 7" long $75.00

Installation Instructions for AS-9 Amalgam Separator

 

 Central Vacuum System: 2-4 chairs

  1. Install the ASDEX Manifold Head Assembly (2000D) in a location as close to vacuum pump as practical.

  2. The system needs to be mounted in a vertical position.

  3. Do not remove ty-wrap from manifold until manifold installation is complete.

  4. Use mounting bracket (MBK-1) to mount manifold.

  5. Out port (note arrow) goes to vacuum pump, in port (note arrow) goes to vacuum line leading to dental operatory.

  6. Remove and save the two disposal caps from the ASDEX Separator.

  7. Before installing ASDEX AS-20 Amalgam Separator remove ty-wrap from manifold head assembly.

 

  Chair Side: Single Chair

  1. Install the ASDEX Manifold Assembly near chair.

  2. The system needs to be mounted in a vertical position.

  3. Do not remove ty-wrap from manifold until manifold installation is complete.

  4. Use mounting bracket (MBK-1) to mount manifold.

  5. Out port (note arrow) goes to vacuum pump, in port (note arrow) goes to mouthpiece.

  6. Remove and save the two disposal caps from the ASDEX Separator.

  7. Before installing ASDEX AS-20 Amalgam Separator remove ty-wrap from manifold head assembly

 How do I know when to replace the separator

For 2-4 operatory dental practice the original separator may require replacement in about 1.5 years. When the separator is 90% full, your vacuum in the mouthpiece will be low and continue to go lower.

You will need to do the following:

  1. Order #AS-20 replacement separator: call 800-422-3520
  2. Contact "Maguire & Strickland" to order prepaid waste recycling & disposal  service. Call 800-486-2858. They are based in Minneapolis, MN. Their charge as of January 6th 2009 is $89.95 KAB Dental is not associated with any recyclers.

Click Here for Information of other Approved Amalgam Recyclers.