ASDEX AS-9 Amalgam Separator
(ISO 11143 Certified ISO Rated 99.0%)

(2000D & MBK-1)
Single Chairside System Portable System/Mobile System
| Item # |
Description |
Price |
| AS10S |
Complete System
Includes: 1 Manifold Head Assembly, 1-Mount Bracket, 1-Replacement Separator
(as-10) 14" long |
$233.00 |
| 2000D |
Manifold Head Assembly |
$104.00 |
| MBK-1 |
Mounting Bracket |
$30.00 |
| AS-10 |
Replacement Separator 14" long |
$90.00 |
Mounting Space Required: 5"x14"
Average Life: 4-8 Months
Flow Rate: 1L/MN ISO Rated: 99.0%
Replacement Schedule: When vacuum is depleted to mouthpiece or 1 year.
Dispose in accordance with any and all local, State & Government guidelines. |
Central Vacuum System 2-4 Chairs
| Item # |
Description |
Price |
| AS20S |
Complete System
Includes: 1-Manifold Head Assembly, 1-Mounting Bracket, 1-Replacement Separator (as-20) 24" long |
$332.00 |
| 2000D |
Manifold Head Assembly |
$104.00 |
| MBK-1 |
Mounting Bracket |
$30.00 |
| AS-20 |
Replacement Separator 24" long |
$198.00 |
Mounting Space required 5"x 24"
Average Life: 4-8 Months
Flow Rate: 1L/MN ISO Rated: 99.0%
Replacement Schedule: When vacuum is depleted to mouthpiece or 1 year.
Dispose in accordance with any and all local, State & Government guidelines. |
For Portable & Mobile Systems
| Item # |
Description |
Price |
| AS5S |
Complete System
Includes: 1 Manifold Assembly, 1-Mount Bracket, 1-Replacement Separator (AS-5) 7" Long |
$204.00 |
| 200D |
Manifold Head Assembly |
$104.00 |
| MBK-1 |
Mounting Bracket |
$130.00 |
| AS-5 |
Replacement Separator 7" long |
$75.00 |
Installation Instructions for AS-9 Amalgam Separator
Central Vacuum System: 2-4 chairs
-
Install the ASDEX Manifold Head Assembly (2000D) in a location as close to vacuum pump as practical.
-
The system needs to be mounted in a vertical position.
-
Do not remove ty-wrap from manifold until manifold installation is complete.
-
Use mounting bracket (MBK-1) to mount manifold.
-
Out port (note arrow) goes to vacuum pump, in port (note arrow) goes to vacuum line leading to dental operatory.
-
Remove and save the two disposal caps from the ASDEX Separator.
-
Before installing ASDEX AS-20 Amalgam Separator remove ty-wrap from manifold head assembly.
Chair Side: Single Chair
-
Install the ASDEX Manifold Assembly near chair.
-
The system needs to be mounted in a vertical position.
-
Do not remove ty-wrap from manifold until manifold installation is complete.
-
Use mounting bracket (MBK-1) to mount manifold.
-
Out port (note arrow) goes to vacuum pump, in port (note arrow) goes to mouthpiece.
-
Remove and save the two disposal caps from the ASDEX Separator.
-
Before installing ASDEX AS-20 Amalgam Separator remove ty-wrap from manifold head assembly
|
How do I know when to replace the separator
For 2-4 operatory dental practice the original separator may require replacement in about 1.5 years. When the separator is 90% full, your vacuum in the mouthpiece will be low and continue to go lower.
You will need to do the following:
- Order #AS-20 replacement separator: call 800-422-3520
- Contact "Maguire & Strickland" to order prepaid waste recycling & disposal service. Call 800-486-2858. They are based in Minneapolis, MN. Their charge as of January 6th 2009 is $89.95 KAB Dental is not associated with any recyclers.
Click Here for Information of other Approved Amalgam Recyclers. Top |
|
| |